title: "Preset Status Report"
canonical: "https://docs.rubiconwater.com/space/RptNC/1987412199/Preset%20Status%20Report"
format: markdown
---
> Macro (toc)

# Report Description

The Preset Status report lists all enabled presets for a specified network object or for all objects in a specified area or group. Use this report to confirm that outlets and regulators are correctly configured to deliver the expected network events. 

> ℹ️ **Example**
> ℹ️ 
> ℹ️ A Planner might use this report to ensure that any changes made to orders have been correctly entered as presets for the network objects.

# Report Parameters and Options

| **Parameter** | **Description** |
| --- | --- |
| Area/Group | Select an area or group for the report |
| Object | Optionally specify a single regulator or outlet for which to run the report. If you don't specify and object, the report will run for all objects in the area/group. |
| Order by | Specify how the report output should be sorted, the options are:<br>- **Name** - sort by the name of the network object. This is the default sorting option.
- **Time due** - sort by the preset start time. |
| Future times only | Include only presets that are due at some future time. (That is, exclude presets in the past.) |

# Report Output

If you have selected a specific object for the report, the table will show the details for that object. Otherwise there will be two tables - one for regulators, and one for outlets.

The report has been modified to include only presets with *Enabled* status. Earlier versions of the report may include presets that are not enabled.

| **Field** | **Description** |
| --- | --- |
| Outlet or Regulator | Object name for this preset |
| Channel Name | Name of the channel to which the object is connected. |
| Preset Slot No | Preset slot number (up to 6 presets can be entered for an object) |
| Preset Time | Date and time when the preset will be implemented |
| Control Mode | Control mode that the preset will apply |
| Setpoint Value | Value that the relevant setpoint will move to when the preset is applied |
| Hours Due | Hours until the preset start time. Negative start times are in the past. |

---